Crozuet KNA3-XS 85100036 Safety Relay, TU2R1 88865305 Timer Lot of 7 (8777)W

No longer available

Crozuet KNA3-XS 85100036 Safety Relay, TU2R1 88865305 Timer Lot of 7 (8777)W

$220 (USD)

Goleta, CA

Description

Crozuet KNA3 XS 85100036 Safety Relay, TU2R1 88865305 Timer Lot of 7 (8777)W Good cosmetic condition with some signs of use. Taken from a working environment . See pictures for more detail. Manufacturer: Crouzet, Moeller, FAZ Model #/ Model: KNA3 XS 85100036, TU2R1 88865305, DIL0M-G, FAZ-C16, FAZ-C10 Included: Note* this data was taken from an online source and may not pertain to this particular item. Crouzet KNA3 XS 85100036 Safety Relay Power Supply: Power supply voltage: ~ 24 V 50/60 Hz Operating Range: -15% / +10% of Un for On/off indication: 1 power supply voltage LED Accuracy: Reset time: < 25 ms Maximum response time on emergency stop: <50 ms Output Specifications: Type: Volt-free outputs No. of safety circuits: 3 N/O" AgSnO 2 contacts No. of data circuits: 1 N/C" AgSnO 2 contacts Breaking capacity: 1500 VA resistive Max. current breaking capacity: 6.82 A Max. voltage breaking capacity: 440 VAC Electrical life: 10 5 operations at 1500 VA resistive 5.10 5 operations at 500 VA resistive Mechanical life: 10 7 operations Operation and Use: Max. absorbed power: AC 1.6 VA / DC 2 W On/off indication:1 internal relay status LED Operating temperature: 0C to +50C acc. to IEC 68-2-14 Storage temperature: -20C to +70C acc. to IEC 68-1/2 Internal voltage: 24 Vc Dielectric strength: 2.95 kV according to IEC 664-1 Resistance to tracking: Material group III INCLUDES: Crouzet TU2R1 88865305 Timer Timing: 0.1s - 100h Output: 2 timed changeover relays Nominal rating: 8A Connections: Screw terminals Supply Voltage: 24 VDC / 24-240 VAC Two Moeller DIL0M-G Contactor Rated Current: 9 A Heat dissipation per hole: 0.3W Operating ambient temperature min.: -25C Operating ambient temperature max.: +50C FAZ-C16 Circuit Breaker Rated operational voltage: 240/415 VAC Rated operational voltage: 60 (per pole) VDC Rated voltage according to UL: 277 VAC Rated switching capacity acc: 15 kA Two FAZ-C10 Circuit Breaker Rated operational voltage: 277/480 VAC Rated switching capacity: 15 kA Breaking capacity according to UL: 10 Weight: 5 Lb Dimensions: LxWxH": 6x6x6" Sold as is with 30 day Right of Return, only pictured items included Easy return/refund for any reason Anacapa Equipment RETURNS Anacapa Equipment Brokers, Inc. (Seller) strives to offer excellent customer service. You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent. We DO NOT ship internationally. If you are using a freight forwarder then returns are VOID. SHIPPING All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment. We only charge actual shipping cost. If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally. IF you are using a freight forwarder then returns are VOID. LIMITED WARRANTY Buyer acknowledges that the equipment is being sold as is" and without any warranty of merchantability or fitness for a particular use. The entire risk as to the quality and performance of the equipment is with the Buyer. Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair. Buyer may inspect the equipment prior to purchase and placement of the order. Failure to inspect prior to placement of an order is deemed a waiver of Buyers right to inspect. Buyer is responsible for determining the suitability of the equipment for its application. Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased. The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty . INDEMNITY Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (Indemnitees) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller. The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws. Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.

Specifications

ManufacturerCrouzet,
ModelKNA3 XS 85100036, TU2R1 88865305, DIL0M-G, FAZ-C16
ConditionUsed
Power supply voltage~ 24 V 50/60 Hz
Operating Range-15% / +10% of Un for
On/off indication1 internal relay status LED
Reset time< 25 ms
Maximum response time on emergency stop<50 ms
TypeVolt-free outputs
No. of safety circuits3 N/O" AgSnO
No. of data circuits1 N/C" AgSnO
Breaking capacity1500 VA resistive
Max. current breaking capacity6.82 A
Max. voltage breaking capacity440 VAC
Electrical life10
Mechanical life10
Max. absorbed powerAC 1.6 VA / DC 2 W
Operating temperature0C to +50C acc. to IEC 68-2-14
Storage temperature-20C to +70C acc. to IEC 68-1/2
Internal voltage24 Vc
Dielectric strength2.95 kV according to IEC 664-1
Resistance to trackingMaterial group III
Timing0.1s - 100h
Output2 timed changeover relays
Nominal rating8A
ConnectionsScrew terminals
Supply Voltage24 VDC / 24-240 VAC
Rated Current9 A
Heat dissipation per hole0.3W
Operating ambient temperature min.-25C
Operating ambient temperature max.+50C
Rated operational voltage277/480 VAC
Rated voltage according to UL277 VAC
Rated switching capacity acc15 kA
Rated switching capacity15 kA
Breaking capacity according to UL10
Weight5 Lb