Lonza, Cambrex 57040 FlashGel Camera, FlashGel 57025, Electrophoresis (8687)W

No longer available

Lonza, Cambrex 57040 FlashGel Camera, FlashGel 57025, Electrophoresis (8687)W

$475 (USD)

Goleta, CA

Description

Lonza, Cambrex 57040 FlashGel Camera, FlashGel 57025, Electrophoresis (8687)W Good cosmetic condition with some signs of use. Both flash gel docks turn on and light up. The flashGel camera is in good cosmetic shape but unable to test. Software not included. See pictures for more detail. Manufacturer: Lonza, Cambrex Model #/ Model: 57040 & 57025 Description: 5 7040 The FlashGel Camera captures data from the FlashGel System and allows you to say goodbye to darkrooms and UV light. Complete separation and documentation safely, at your bench, in minutes. This simple digital camera in an enclosed hood connects directly to your laptop or PC via USB cable. 57025 The FlashGel Dock is the basis for the FlashGel System and is required to run the FlashGel Cassettes. It can be purchased as a stand alone or as part of a kit. The FlashGel System for fast electrophoresis of DNA is the ideal tool for quick screening of up to 32 samples without having to plan your day around agarose gels. The FlashGel System is the fastest way to separate DNA and the best way to watch DNA migration on the FlashGel Dock as it happens. This revolutionary new tool separates DNA in 2 - 7 minutes. Monitor gel runs right at the bench, without UV light. The highly sensitive system allows a 5-20X reduction in DNA levels - saving both time and money. (Taken from manufacturer website). Applications: DNA Electrophoresis RNA Electrophoresis Included: One Lonza 57040 FlashGel Camera Two Lonza 57025 FlashGel Dock One Power Supply Two Electrodes Specifications: Note* this data was taken from an online source and may not pertain to this particular model. Maximum Limits: Electrophoresis unit: 0 - 300 VDC High Voltage DC Input 15 Watts Power 50 mA current Dock light: 18 VDC low voltage DC input Environmental Conditions: Temperature: 15C-35C Humidity: 15%-85% relative humidity, non-condensing For indoor use only Altitude up to 2000m Benefits: 5 minute separation and recovery, See bands in as little as 2 minutes Recover samples directly without UV light band excision or purification Real-time separation and documentation Watch band migration as it happens Photograph gels at the bench without DNA damaging UV light Outstanding sensitivity and resolution Weight: 3 Lb Dimensions: LxWxH": 8x6x6" Sold as is with 30 day Right of Return, only pictured items included Easy return/refund for any reason Anacapa Equipment RETURNS Anacapa Equipment Brokers, Inc. (Seller) strives to offer excellent customer service. You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent. We DO NOT ship internationally. If you are using a freight forwarder then returns are VOID. SHIPPING All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment. We only charge actual shipping cost. If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally. IF you are using a freight forwarder then returns are VOID. LIMITED WARRANTY Buyer acknowledges that the equipment is being sold as is" and without any warranty of merchantability or fitness for a particular use. The entire risk as to the quality and performance of the equipment is with the Buyer. Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair. Buyer may inspect the equipment prior to purchase and placement of the order. Failure to inspect prior to placement of an order is deemed a waiver of Buyers right to inspect. Buyer is responsible for determining the suitability of the equipment for its application. Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased. The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty . INDEMNITY Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (Indemnitees) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller. The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws. Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.

Specifications

ManufacturerLonza, Cambrex
Model57040, 57025
ConditionUsed
Model #/ Model57040 & 57025
Electrophoresis unit0 - 300 VDC High Voltage DC Input
Dock light18 VDC low voltage DC input
Temperature15C-35C
Humidity15%-85% relative humidity, non-condensing
Weight3 Lb