Anderson Instrument SL5004120100000 Hydrostatic Level Transmitter (7746)W
No longer available
Anderson Instrument SL5004120100000 Hydrostatic Level Transmitter (7746)W
$190 (USD)
Goleta, CA
Description
Anderson Instrument SL5004120100000 Hydrostatic Level Transmitter (7746)W
Item is in good cosmetic condition with some signs of use. Unable to test. See pictures for more details.
Manufacturer: Anderson Instrument
Model #/ Model:
SL5004120100000
Includes:
Anderson Instrument SL5004120100000 Hydrostatic Level Transmitter
High Pressure Clamp
Specifications:
Note*
This data was taken from an online source and may not pertain to this particular model.
Span Range: 0-30" min to 0-140" max
Fitting: 1-1/2" Tri-Clamp
Diaphragm: SS-316L Electropolished
Mounting: Other
Sensor Wiring: Quick Disconnect Receptacle (QDR) & Field Wire-able Connector (FWC) w/no Cable (std.)
Calibration: Field Calibrated
Calibration Accuracy:(Includes repeatability, hysteresis, and linearity) 0.20%
Calibration Stability: Within +/-0.2% of URL for one year minimum
Resolution: Infinite
Process Temperature Limits: 0F to 265F (-18C to 130C)
Ambient Temperature:
15F to 120F (-9C to 49C)
Compensated Temperature: 0F to 250F (-18C to 121C)
Temperature Stability: 0.2% of Upper Range Limit (URL) per 10F (5.5C)
Response Time: 526 mSec
Excitation:
24
(12-36 vdc)
Input Current Rating: 35mA
Input: 12-40 VDC
Output: 4-20mA dc, 2-wire. Internal test points supplied
Loop Resistance:
1550 ohms (max.) at 40 vdc, 750 ohms (max) at 24 vdc
Weight: 3 Lb
Dimensions: LxWxH": 6x3x3"
Sold as is with 30 day Right of Return, only pictured items included
Easy return/refund for any reason
Anacapa Equipment
RETURNS
Anacapa Equipment Brokers, Inc. (Seller) strives to offer excellent customer service. You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent. We DO NOT ship internationally. If you are using a freight forwarder then returns are VOID.
SHIPPING
All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment. We only charge actual shipping cost. If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost.
We DO NOT ship internationally. IF you are using a freight forwarder then returns are VOID.
LIMITED WARRANTY
Buyer acknowledges that the equipment is being sold as is" and without any warranty of merchantability or fitness for a particular use. The entire risk as to the quality and performance of the equipment is with the Buyer. Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair. Buyer may inspect the equipment prior to purchase and placement of the order. Failure to inspect prior to placement of an order is deemed a waiver of Buyers right to inspect. Buyer is responsible for determining the suitability of the equipment for its application. Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.
The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty
.
INDEMNITY
Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (Indemnitees) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller. The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws. Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.
Specifications
Manufacturer | Anderson Instrument |
Model | SL5004120100000 |
Condition | Used |
Span Range | 0-30" min to 0-140" max |
Fitting | 1-1/2" Tri-Clamp |
Diaphragm | SS-316L Electropolished |
Mounting | Other |
Sensor Wiring | Quick Disconnect Receptacle (QDR) & Field Wire-able Connector (FWC) w/no Cable (std.) |
Calibration | Field Calibrated |
Calibration Accuracy | (Includes repeatability, hysteresis, and linearity) 0.20% |
Calibration Stability | Within +/-0.2% of URL for one year minimum |
Resolution | Infinite |
Process Temperature Limits | 0F to 265F (-18C to 130C) |
Compensated Temperature | 0F to 250F (-18C to 121C) |
Temperature Stability | 0.2% of Upper Range Limit (URL) per 10F (5.5C) |
Response Time | 526 mSec |
Input Current Rating | 35mA |
Input | 12-40 VDC |
Output | 4-20mA dc, 2-wire. Internal test points supplied |
Weight | 3 Lb |
​Weight | 3 Lb |