Alpha Technologies 89002 APA 2000 Advanced Polymer Analyzer Rheometer (7251)R

No longer available

Alpha Technologies 89002 APA 2000 Advanced Polymer Analyzer Rheometer (7251)R

$16,500 (USD)

Goleta, CA

Description

Alpha Technologies 89002 APA 2000 Advanced Polymer Analyzer USED (7251)R In good cosmetic condition. Powers on, buttons respond well to input. Stepper motor respond well to input. The door and platens open and shut. Unable to test further, software NOT included. See pictures for more detail. Watch Video Here: https://www.youtube.com/watch?v=n34sUsdP_AY The following article taken from PT online describes this Rheometer: Manufacturer: Alpha Technologies Model: 89002 | APA 2000 Type:Advanced Polymer Analyzer Year: 2004 120 VAC / 15 Amps 50/60 Hz 1800 VA Air Pressure Max: 120 Min: 70 Actual Dimensions: LxWxH": 27x30x52" Shipping Dimensions: ~40x48x60 Actual Weight: 300 lbs Shipping Weight:~ 450 lbs A unique type of oscillating-die rheometer, first unveiled in 1999 for analyzing thermosets and composites, has now been upgraded for testing polyolefins and other thermoplastics. This instrument reportedly provides more information about the processing characteristics of resinsdata that previously required two or more instruments at much higher cost. The APA 2000 Advanced Polymer Analyzer was developed by Alpha Technologies, a maker of laboratory instrumentation for rubbers and other polymers, which became a business unit of Dynisco LLC last year. According to Tom Mlinar, Alphas v.p., of sales and services, the updated APA 2000 is unique in its ability to fully characterize polymers in a single test, measuring the dynamic mechanical properties before, during and after cure (for thermosets) or melt solidification. Plastics processors and compounders can simulate exact process conditions to determine the impact of processing on part quality and performance. Test capabilities include isothermal cure, controlled stress or strain, linear or nonlinear temperature ramps, temperature sweeps, frequency sweeps, and strain sweeps. Mlinar says that to obtain the breadth of information achievable with this one instrument would typically require tests on a Mooney rheometer plus a DMA (dynamic mechanical analyzer) and probably also a capillary rheometer. The APA 2000 is about twice the cost of a typical Mooney or capillary rheometer, yet half the cost of a DMA. The APA 2000 has a special temperature-control system, a sealed and pressurized sample cavity, and a unique sample handling technique, all of which are said to contribute to highly repeatable measurements of viscosity, gel time, cure time, crystallization rate, final shear modulus, and glass-transition temperature (Tg). The unit is also reportedly simple to use, with even the most complex tests programmed and data retrieved easily via the systems multi-tasking operator interface. Minimal sample preparation time is required and testing is initiated by a single keystroke. Crating Fee: Ask For Quote Sold as is with 30day Right of Return, only pictured items included Easy return/refund for any reason Anacapa Equipment RETURNS Anacapa Equipment Brokers, Inc. (Seller) strives to offer excellent customer service. You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent. We DO NOT ship internationally. If you are using a freight forwarder then returns are VOID. SHIPPING All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment. We only charge actual shipping cost. If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally. IF you are using a freight forwarder then returns are VOID. LIMITED WARRANTY Buyer acknowledges that the equipment is being sold as is" and without any warranty of merchantability or fitness for a particular use. The entire risk as to the quality and performance of the equipment is with the Buyer. Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair. Buyer may inspect the equipment prior to purchase and placement of the order. Failure to inspect prior to placement of an order is deemed a waiver of Buyers right to inspect. Buyer is responsible for determining the suitability of the equipment for its application. Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased. The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty . INDEMNITY Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (Indemnitees) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller. The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws. Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.

Specifications

ManufacturerAlpha Technologies
Model89002 | APA 2000
Year2004
ConditionUsed
Https//www.youtube.com/watch?v=n34sUsdP_AY
TypeAdvanced Polymer Analyzer
Max120
Min70
Shipping Dimensions~40x48x60
Actual Weight300 lbs
Shipping Weight~ 450 lbs
Crating FeeAsk For Quote