Waters 2695 Separations Module HPLC w/ 2475 Multi Fluoresce USED (7253)RIn good cosmetic condition. See pictures for more detail. Powers on, digital screen and buttons respond well to detail. Passes all initial test. Unable to test further. The Lamp, Solvent Hoses, and Filters may need to be replaced. See pictures for more detail.Manufacturer: WatersModel #/ Model: 2695 | 2475Includes:2695 Separations Module WAT270008Syringe Assembly Model: SM4 (Syringe is NOT included)SCH Sampler Heater/Cooler Unit: 2890005602475 Multi Fluorescence Detector 186002475Column Heater/Cooler Model: 186001791Specifications: (These specifications were taken from an online datasheet and may not be accurate to this product. See pictures for more detail.)2695 Separations ModuleNumber of solvents: One to fourSolvent conditioning: Vacuum degas, two (2) operating modes, four (4) chambers, <500 uL internal volume per chamber> <500uL interval volume per chamberProgrammable flow rate range: 0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min. incrementsTypical operating flow rate range: 0.050 to 5.000 mL/min in 0.001-mL/min incrementsCompressibility compensation: Automatic and continuousEffective system delay volume: <650 L, independent of backpressure @ 1 mL/minPlunger seal wash: Integra, active, programmableGradient profiles: Eleven (11) gradient curves [including linear, step (2 curves), concave (4 curves), and convex (4 curves)]Dry prime/wet prime: Automatic, front panel controlFlow ramping: Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rateMaximum operating pressure: 5000 psi (345 bar) (0.010 to 3.000 mL/min) Programmable upper and lower limits. Pressure fall-off at >3.000 mL/min.Pressure ripple: 2.5% (1 mL/min, degassed methanol, at 1700 psi backpressure)Composition accuracy: 0.5% absolute, independent of backpressure (Proportioning Valve Pair Test [degassed methanol:methanol/propylparaben, 2 mL/min, 254 nm])Composition precision: 0.15% RSD or 0.02 min SD, whichever is greater, based on retention time. (Degassed methanol:water 60:40 Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 254 nm.)Flow precision: 0.075% RSD or 0.02 min SD, based on retention time (N = 6) or volumetric measures (0.200 to 5.000 mL/min), isocratic premixFlow accuracy: 1% or 10 L/min, whichever is greater, (0.200 to 5.000 mL/ min), degassed methanol, at 600 psi backpressure2475 Multi Fluorescence DetectorWavelength repeatabilty: + 0.25nmSensitivity, single channel:Ex: 350 nmEm: 397 nmSensitivity Setting Range: 1 to 100,000 EUFSFilter Setting Range:Single Channel:0.1 to 5.0 seconds Hamming (default)0.1 to 99 seconds, RCMultichannel:1 to 50 seconds, Hamming (default)1 to 99 seconds, RCCell Volume: 8uLShipping:Actual Weight:~190 lbsShipping Weight:Actual Dimensions: (LxWxH): 24x26x32"Shipping Dimensions:Crating Fee: $250 Waters 2695 Separations Module HPLC w/ 2475 Multi Fluorescence Detector and Column Heater USED (7255)R In good cosmetic condition. See pictures for more detail. Powers on, digital screen and buttons respond well to detail. Passes all initial test. Unable to test further. The Bulb, Solvent Hoses, and Filters may need to be replaced. See pictures for more detail. SM4 289000560 186002475 186001791 Includes: 2695 Separations Module WAT270008 2475Multi Fluorescence Detector 186002475 Specifications: (These specifications were taken from an online datasheet and may not be accurate to this product. See pictures for more detail.) 2695 Separations Module Solvent conditioning: Vacuum degas, two (2) operating modes, four (4) chambers, <500 uL internal volume per chamber> <500uL interval volume per chamber Programmable flow rate range: 0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min. increments Typical operating flow rate range: 0.050 to 5.000 mL/min in 0.001-mL/min increments Gradient profiles: Eleven (11) gradient curves [including linear, step (2 curves), concave (4 curves), and convex (4 curves)] Flow ramping: Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate Maximum operating pressure: 5000 psi (345 bar) (0.010 to 3.000 mL/min) Programmable upper and lower limits. Pressure fall-off at >3.000 mL/min. Composition accuracy: 0.5% absolute, independent of backpressure (Proportioning Valve Pair Test [degassed methanol:methanol/propylparaben, 2 mL/min, 254 nm]) Composition precision: 0.15% RSD or 0.02 min SD, whichever is greater, based on retention time. (Degassed methanol:water 60:40 Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 254 nm.) Flow precision: 0.075% RSD or 0.02 min SD, based on retention time (N = 6) or volumetric measures (0.200 to 5.000 mL/min), isocratic premix Flow accuracy: 1% or 10 L/min, whichever is greater, (0.200 to 5.000 mL/ min), degassed methanol, at 600 psi backpressure 2475Multi Fluorescence Detector Sensitivity, single channel: Filter Setting Range: Single Channel: 0.1 to 5.0 seconds Hamming (default) 0.1 to 99 seconds, RC Multichannel: 1 to 50 seconds, Hamming (default) 1 to 99 seconds, RC Shipping: Actual Dimensions:(LxWxH): 24x26x32" Sold as is with 30day Right of Return, only pictured items included Easy return/refund for any reason RETURNS Anacapa Equipment Brokers, Inc. (Seller) strives to offer excellent customer service. You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent. We DO NOT ship internationally. If you are using a freight forwarder then returns are VOID. SHIPPING All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment. We only charge actual shipping cost. If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally. IF you are using a freight forwarder then returns are VOID. LIMITED WARRANTY Buyer acknowledges that the equipment is being sold as is" and without any warranty of merchantability or fitness for a particular use. The entire risk as to the quality and performance of the equipment is with the Buyer. Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair. Buyer may inspect the equipment prior to purchase and placement of the order. Failure to inspect prior to placement of an order is deemed a waiver of Buyers right to inspect. Buyer is responsible for determining the suitability of the equipment for its application. Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased. The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty . INDEMNITY Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (Indemnitees) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller. The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws. Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.

Specifications

ManufacturerWaters
ConditionUsed
Model #/ model2695 | 2475
Syringe assembly modelSM4 (Syringe is NOT included)
Sch sampler heater/cooler unit289000560
Column heater/cooler model186001791
Number of solventsOne to four
Compressibility compensationAutomatic and continuous
Effective system delay volume<650 L, independent of backpressure @ 1 mL/min
Plunger seal washIntegra, active, programmable
Dry prime/wet primeAutomatic, front panel control
Pressure ripple2.5% (1 mL/min, degassed methanol, at 1700 psi backpressure)
Wavelength repeatabilty+ 0.25nm
Ex350 nm
Em397 nm
Sensitivity setting range1 to 100,000 EUFS
Cell volume8uL
Actual weight~190 #
Shipping weight240#
Shipping dimensions36 X 32 X 38 "WDH 240#
Crating feeAsk For Quote