New Brunswick Celligen BLU-120-LOA Benchtop Cell Culture System Bioreactor (9707

New Brunswick Celligen BLU-120-LOA Benchtop Cell Culture System Bioreactor (9707
$14,500 (USD)
Goleta, CA
orCall (805)-6364334
Description
New Brunswick Celligen BLU-120-LOA Benchtop Cell Culture System Bioreactor USED (9707)R
In good cosmetic condition. Screen responds well to input. The Pumps andDrive Motorturn on and spin well. no further testing done. Scale is included but the Benchtop System is missing the port and cannot be connected. See pictures for more detail.
Manufacturer:
New Brunswick Eppendorf
Model: BLU-120-LOA
Also Includes:
IDS ESM60A(I)-C2Drive Motor
PH Cable
DO Cable
ExhaustTubeHeated Blanket
Cable for Temperature Probe
Scale (The Benchtop System is missing the port and cannot be connected. See Pictures)
Elo Touch Screen Monitor
x3 Peristaltic Pump
Power Cable
Specifications:
The following specifications were taken from an online user manual or manufacturer's website and may not be specific to this item, please look at pictures carefully for items included and specifics. These specifications are for reference only.
Single-Use Cell Culture Vessel
Total Volume: 5.0 Liters 14.0 Liters
Working Volume: 3.75 Liters 10.5 Liters
Minimum Volume: 1.25 Liters 3.5 Liters
Control Station
Controls up to 32 control loops; stores 10 recipes and 8 process variables for trend graphing.
Includes an industrial touchscreen monitor/user interface, 3 built-in pumps and connectors for
all utilities and communications signals.
Touchscreen Interface/Display 15-inch (38.1 cm) color industrial monitor with adjustable-angle swivel
Temperature
Indication: Digital display in 0.1C increments
Range: From 5C above ambient temperature to 40C
Control: P&I for heating using a Heat Blanket (cooling via ambient environment)
Sensor: Platinum RTD probe
Agitation
Drive: Permanent magnet motor with high torque input
Indication: Digital display in 1 rpm increments
Range: 25 - 200 rpm
Control: PI-controlled
Impellers: Pitched blade (upflow or downflow selectable via touchscreen)
Exhaust
Filter: 0.2 m disposable filter
Tube: Heat blanketed (Included)
Aeration
3- or 4-Gas System: Up to 4 gases, including air, N2, CO2 and O2, delivered to sparge and overlay
Flow Control: Automatic or manual options
Sparge: 1, 3 or 4 TMFCs (0.002 - 0.1 SLPM) Automatic option
1 Rotameter (0.001 - 0.1 SLPM) Manual option
Sparge Element: Porous microsparger (6 - 12 m)
Inlet Filters: 0.2 m disposable filter
pH
Indication: Digital display in 0.01 pH increments
Range: 6 - 8 pH
Control: P&I
Probe: Noninvasive optical pH probe. Single-use fluorescence sensor is included with each vessel
DO
Indication: Digital display in 0.1% increments
Range: 0 - 200%
Control: P&I
Probe: Noninvasive, reusable polarographic probe
Pumps
Pump 1:
Assignable high-performance peristaltic pump
Fixed speed (14 rpm) or variable-duty cycle
Available control modes: Off, On, Prime
Pumps 2 and 3:
Assignable high-performance peristaltic pumps
Fixed speed (109 rpm) or variable-duty cycle
Available control modes: Off, On, Prime
Utilities
(Gas): 5 - 6 PSIG maximum
Electrical Requirements
100 - 120 VAC 50/60 Hz, Single phase, 15 Amps
Dimensions
Actual Dimensions(Blu Culture System): 21x21x32"
Actual Weight:88lbs
Shipping Dimensions: 36x32x38"
Shipping Weight:~165 lbs
Crating Fee: Ask For A Quote
Sold as is with 30day Right of Return, only pictured items included
Easy return/refund for any reason
Anacapa Equipment
RETURNS
Anacapa Equipment Brokers, Inc. (Seller) strives to offer excellent customer service. You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent. We DO NOT ship internationally. If you are using a freight forwarder then returns are VOID.
SHIPPING
All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment. We only charge actual shipping cost. If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost.
We DO NOT ship internationally. IF you are using a freight forwarder then returns are VOID.
LIMITED WARRANTY
Buyer acknowledges that the equipment is being sold as is" and without any warranty of merchantability or fitness for a particular use. The entire risk as to the quality and performance of the equipment is with the Buyer. Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair. Buyer may inspect the equipment prior to purchase and placement of the order. Failure to inspect prior to placement of an order is deemed a waiver of Buyers right to inspect. Buyer is responsible for determining the suitability of the equipment for its application. Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.
The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty
.
INDEMNITY
Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (Indemnitees) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller. The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws. Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.
Specifications
Model | BLU-120-LOA |
Condition | Used |
Seller notes | “In good cosmetic condition. Screen responds well to input. The Pumps and Drive Motor turn on and ... Read moreabout the seller notes“In good cosmetic condition. Screen responds well to input. The Pumps and Drive Motor turn on and spin well. No further testing done. Scale is included but the Benchtop System is missing the port and cannot be connected. See pictures for more detail.” Read Lessabout the seller notes |
Total volume | 5.0 Liters 14.0 Liters |
Working volume | 3.75 Liters 10.5 Liters |
Minimum volume | 1.25 Liters 3.5 Liters |
Indication | Digital display in 0.1% increments |
Range | 0 - 200% |
Control | P&I |
Sensor | Platinum RTD probe |
Drive | Permanent magnet motor with high torque input |
Impellers | Pitched blade (upflow or downflow selectable via touchscreen) |
Filter | 0.2 m disposable filter |
Tube | Heat blanketed (Included) |
3- or 4-gas system | Up to 4 gases, including air, N2, CO2 and O2, delivered to sparge and overlay |
Flow control | Automatic or manual options |
Sparge | 1, 3 or 4 TMFCs (0.002 - 0.1 SLPM) Automatic option |
Sparge element | Porous microsparger (6 - 12 m) |
Inlet filters | 0.2 m disposable filter |
Probe | Noninvasive, reusable polarographic probe |
Available control modes | Off, On, Prime |
(gas) | 5 - 6 PSIG maximum |
Actual dimensions(blu culture system) | 21x21x32" |
Actual weight | 88lbs |
Shipping dimensions | 36x32x38" |
Shipping weight | ~165 lbs |
Crating fee | Ask For A Quote |