Biospherix ProOx P110 Compact CO2 Controller USED (9504)R

No longer available
Biospherix ProOx P110 Compact CO2 Controller USED (9504)R
$475 (USD)
Goleta, CA
Description
BiospherixProOx P110Compact CO2 Controller USED (9504)R
In good cosmetic condition. Digital Screen and buttons respond well to input. "Input Failure" is displayed but we believe that is because the Sensors are NOT included. Alarm works. See pictures for more detail.
Manufacturer:
Biospherix
Model:ProOx P110
Power 12 VDC 300 MA
Max Gas Pressure 25 PSI
Also Includes: Power Supply
Specifications:
The following specifications were taken from an online user manual or manufacturer's website and may not be specific to this item, please look at pictures carefully for items included and specifics. These specifications are for reference only.
ELECTRICAL POWER: 12 VDC/2.5A
CONTROL RANGE: 0.1-99.9% oxygen depending on the power/load balance
ACCURACY: 1% at constant temperature/pressure 2% full scale over operating temperature range
RESOLUTION: to 0.1% oxygen, display and set point.
OXYGEN SENSOR: various application specific sensors are available.
GAS SOURCE: compressed gas tanks, liquid carboys (from headspace), or generators.
GAS SUPPLY: pressurized gas.
GAS SUPPLY LINE: 1/8 I.D. pressure rated hose.
GAS SUPPLY LINE PRESSURE: 1-25 P.S.I.G.
GAS INFUSION RATE: 1-35 S.C.F.H.
GAS CONSUMPTION: depends on (1) size and leakiness of hose chamber, (2) frequency and duration of opening chamber doors, and (3) oxygen level controlled.
GAS SUPPLY HOSE FITTING: 1/8 I.D. hose barb.
INFUSION TUBING HOSE FITTING: 1/8 I.D. hose barb.
INFUSION TUBING DIAMETER: 1/4 O.D. x 1/8 I.D. (special tubing sizes available).
INFUSION TUBING LENGTH: 10 ft. (custom lengths available).
Dimensions
Actual Dimensions: 9x4x2"
Actual Weight:
2 lbs
Sold as is with 30day Right of Return, only pictured items included
Easy return/refund for any reason
Anacapa Equipment
RETURNS
Anacapa Equipment Brokers, Inc. (Seller) strives to offer excellent customer service. You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent. We DO NOT ship internationally. If you are using a freight forwarder then returns are VOID.
SHIPPING
All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment. We only charge actual shipping cost. If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost.
We DO NOT ship internationally. IF you are using a freight forwarder then returns are VOID.
LIMITED WARRANTY
Buyer acknowledges that the equipment is being sold as is" and without any warranty of merchantability or fitness for a particular use. The entire risk as to the quality and performance of the equipment is with the Buyer. Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair. Buyer may inspect the equipment prior to purchase and placement of the order. Failure to inspect prior to placement of an order is deemed a waiver of Buyers right to inspect. Buyer is responsible for determining the suitability of the equipment for its application. Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.
The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty
.
INDEMNITY
Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (Indemnitees) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller. The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws. Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.
Specifications
Model | ProOx P110 |
Condition | Used |
Also includes | Power Supply |
Electrical power | 12 VDC/2.5A |
Control range | 0.1-99.9% oxygen depending on the power/load balance |
Accuracy | 1% at constant temperature/pressure 2% full scale over operating temperature range |
Resolution | to 0.1% oxygen, display and set point. |
Oxygen sensor | various application specific sensors are available. |
Gas source | compressed gas tanks, liquid carboys (from headspace), or generators. |
Gas supply | pressurized gas. |
Gas supply line | 1/8 I.D. pressure rated hose. |
Gas supply line pressure | 1-25 P.S.I.G. |
Gas infusion rate | 1-35 S.C.F.H. |
Gas consumption | depends on (1) size and leakiness of hose chamber, (2) frequency and duration of opening chamber doors, and (3) oxygen level controlled. |
Gas supply hose fitting | 1/8 I.D. hose barb. |
Infusion tubing hose fitting | 1/8 I.D. hose barb. |
Infusion tubing diameter | 1/4 O.D. x 1/8 I.D. (special tubing sizes available). |
Infusion tubing length | 10 ft. (custom lengths available). |
Actual dimensions | 9x4x2" |